Why Bidirectional Charging Is Becoming Central to Zero Emission Buildings

By Thomas Hauer, Field Application Engineer and Power Specialist, Avnet Silica
As Europe’s building sector moves toward zero-emission design, energy storage is becoming an increasingly important part of how power is generated, managed, and used. Bidirectional charging (BDC) is helping drive that shift by enabling more flexible integration of onsite renewables, storage, and smart charging. For designers, that creates new opportunities, but also new decisions around topology, efficiency, safety, and scalability.
Buildings and Energy Storage
In Europe, buildings are the largest energy consumers, which places them at the centre of the EU’s transition toward climate neutrality1 . Since 2020, new EU buildings have been required to meet nearly zero energy building standards. By 2030, this will evolve toward zero-emission buildings, with no on-site fossil fuel emissions and higher overall energy performance.
A key implication of this transition is the growing importance of energy storage. Zero-emission buildings will need to integrate electric and thermal energy storage systems to balance supply and demand more effectively. These systems store surplus renewable energy generated onsite for later use, helping to support decentralised generation, better demand response, smart charging, and greater grid flexibility. In this context, power conversion becomes a critical part of overall system design.
How BDC Simplifies Power Conversion
Traditionally, electric vehicles (EVs) use a unidirectional onboard charger (OBC), largely because of cost and the complexity of meeting grid standards for bidirectional operation within the vehicle. BDC has changed this model by enabling controlled two-way power flow between the grid, energy storage, and connected systems.
In building, V2H, and V2G installations, bidirectional conversion is instead handled by the wallbox, charger, or stationary power conversion system, which manages grid synchronisation and energy transfer between the vehicle, storage, and the building. This form of DC bidirectional charging connects directly to the vehicle’s high-voltage DC bus, bypassing the OBC during charging and discharging. As a single point of conversion, this model supports lower system complexity, improved scalability, and more flexible integration of distributed energy resources.
The increased flexibility offered by BDC has enabled a wider range of applications, including the integration of EVs with domestic and grid-level power systems, as well as domestic and commercial-scale energy storage systems.
BDC Design Priorities
When designing a BDC system, engineers must balance efficiency, cost, size, and safety against the specific requirements of the application. Those requirements vary with power level, voltage range, thermal constraints, isolation needs, and the intended bidirectional function, so the design process is shaped by trade-offs rather than a single preferred approach.
One of the first and most important decisions is the choice of conversion topology. Different topologies offer different advantages and disadvantages, which in turn affect the size, cost, and efficiency of the overall power conversion system. The most suitable solution therefore depends on the application, the power tier, and the performance priorities of the design.
The switching control strategy is another key consideration. Depending on the chosen topology, power level, and semiconductor technology, designers may use phase-shift or resonant control techniques and tune parameters such as dead-time to balance efficiency and safe bidirectional operation. Optimising those settings helps minimise switching and conduction losses while preventing unsafe current or voltage stresses.
Safety must also be considered in relation to both power tier and topology. While topologies such as DAB and CLLC provide inherent galvanic isolation through their transformers, designers must still address insulation, fault protection, and regulatory requirements, especially at higher power levels.
Choosing a BDC Topology
Topology choice depends on whether the system is connected through an AC grid interface or coupled directly to a DC bus. Grid-connected bidirectional wallboxes and stationary converters typically combine a grid-facing PFC or inverter stage with an isolated bidirectional DC-DC stage, while DC-coupled systems may place the grid facing stage elsewhere but still require isolation and protection for safe battery integration. For the grid-facing stage, totem-pole PFC can be attractive where high efficiency and lower component count are priorities, although EMC and control complexity must be managed.
In higher-power three-phase systems, Vienna bridge rectifiers are often considered for the grid-facing PFC stage, particularly where efficiency, lower input current distortion, and three-phase operation are priorities. For the isolated DC-DC stage, CLLC and DAB are common, with DAB often favoured where bidirectional control, flexible voltage matching, and robust power regulation are priorities. In building energy systems, these choices directly affect how efficiently storage can be integrated with onsite generation, charging, and wider power management functions.
DAB is particularly versatile because it combines high efficiency with the ability to handle a broad range of input and output voltages. It also operates at constant switching frequency and can deliver lower current ripple than resonant topologies, which simplifies control and supports predictable bidirectional operation, even if packaging density can be slightly lower than some resonant alternatives. That makes it attractive wherever minimising energy loss is important. A DAB comprises two full-bridge H-bridges connected across an isolated high-frequency transformer. Power flows bidirectionally by modulating the phase shift between the primary and secondary bridges, allowing precise regulation of energy transfer while maintaining galvanic isolation.
In practical terms, designers implementing a DAB need to select high speed MOSFETs or power modules, the high-frequency transformer, and passive elements that help manage leakage inductance, switching losses, and soft switching conditions. Avnet Silica’s portfolio supports these design requirements with solutions from leading manufacturers, including onsemi, ROHM Semiconductor, STMicroelectronics, and Nexperia.
The combination of efficiency, isolation, and flexible voltage handling explains why DAB is such an important topology in modern BDC design.
Semiconductor Choices for BDC
Besides topology, semiconductor technology plays a major role in BDC design. Device selection affects switching speed, thermal output, efficiency, and cost. Thus, it has a direct impact on overall converter performance.
IGBTs remain well established and can handle the current requirements of many bidirectional conversion topologies, particularly where lower switching frequencies and cost sensitivity are priorities. However, Silicon carbide (SiC) has better switching-loss and RDS(on) behaviour, making it better suited to higher-voltage designs where converter losses must be minimised. These advantages are especially valuable in three-phase applications, where efficiency, thermal performance, and power density are all important, but they can also support lower-output-power designs where efficiency remains a top priority. At power levels above 10 kW, SiC is prominent in applications such as EV charging and grid scale storage.
Gallium nitride (GaN) fits a different part of the design space. It is currently better suited to compact, lower-voltage, single phase home energy systems or BDCs, where high switching frequency and reduced size can be beneficial. This is partly due to breakdown-voltage limits. Single-phase systems often work with internal DC bus voltages around 400 V, which can align well with 650 V GaN devices. Three-phase systems, however, often operate with internal DC bus voltages closer to 800 V, beyond 650 V GaN devices’ capabilities. Some higher voltage and higher-power GaN solutions are emerging, but SiC remains the more established choice for higher-voltage, higher-power bidirectional systems.
BDC by Power Tier
Power conversion design is shaped by multiple interdependent factors, including efficiency targets, input voltage range, output power, thermal constraints, and the intended bidirectional functionality. The balance of those factors changes significantly across residential, commercial, and industrial systems.
Small residential systems usually operate at lower power levels, but the grid interface may be single-phase 230 V or three-phase 400 V depending on country, grid arrangement, and installation. EV and high-voltage battery interfaces generally require galvanic isolation, so DAB or CLLC may be used for the isolated bidirectional DC-DC stage. Silicon devices can be sufficient at modest power levels, while GaN can be attractive in lower-power, high frequency designs.
Medium-power commercial systems, including Level 2 EV chargers, small-scale microgrids, and building applications aligned with nearly zero energy targets, often operate from a three-phase 400 V supply and demand higher efficiency, power density, and thermal performance. The grid-facing stage may use totem-pole PFC where lower component count and cost are priorities, although EMC and control complexity must be managed. As power levels and three-phase requirements increase, Vienna bridge topology becomes more common. DAB and CLLC suit the isolated bidirectional DC-DC stage, while SiC often becomes preferred for efficiency, thermal performance, and compact design.
At higher power levels, such as EV fast chargers, industrial energy storage, and critical backup power, systems may operate with DC bus voltages of 1000 V to 1200 V or higher and must maintain efficiency under demanding electrical and thermal conditions. Vienna bridge and other multilevel or interleaved power conversion architectures become more prominent on the grid-facing stage, while multi-phase or interleaved DAB and CLLC resonant conversion are relevant for isolated bidirectional DC-DC conversion. SiC MOSFETs and IGBTs, including higher voltage SiC devices, help achieve compact, high-efficiency designs.
Designing for Scale
That is why BDC is becoming central to zero-emission buildings: it supports more efficient energy use and helps extend energy storage into a wider range of applications. For zero-emission buildings, designers need to consider topology, semiconductor selection, control strategy, and safety design together.
Avnet Silica provides the tools, expertise, and components necessary to design and scale BDC systems for a wide range of applications, from home energy systems to grid-scale solutions.
1 https://energy.ec.europa.eu/topics/ energy efficiency/energy-performance-buildings/nearly zero-energy-and-zero-emission-buildings_en